dc.description.abstractThe Baixo Sabor dam is a 123 meters high concrete arch dam located in the north of Portu-gal. After the performance of a forced vibration test, a quite unique experimental programme was initiated in the dam during the first filling of the reservoir, with the installation of a con-tinuous dynamic monitoring system in December 2015. The implementation of such a system aimed to study the evolution of the dam’s dynamic behaviour during the first filling, as well as to monitor its condition in the long-term through the development of vibration-based damage detection supported by robust operational modal analysis. After a description of the dam and the monitoring system, this paper presents an overview of the tools developed to perform the automated tracking of the dam’s modal parameters. Final-ly, using the database collected during the last seven years, the long-term evolution of the dam dynamic parameters is analysed, and their seasonal fluctuations interpreted. The even-tual occurrence of structural anomalies is evaluated after the minimization of the most influ-ential operational and environmental effects on the dam, such as temperature and the reservoir water level.pt_BR
dc.language.isoengpt_BR
dc.publisherInstitute of Structural Analysis and Antiseismic Research School of Civil Engineering National Technical University of Athens (NTUA) Greecept_BR
dc.relationDAM_AGEpt_BR
dc.relation.ispartofseriesISBN:978-618-5827-00-7;pt_BR
dc.rightsopenAccesspt_BR
dc.subjectoperational modal analysispt_BR
dc.subjectcontinuous dynamic monitoringpt_BR
dc.subjectdam monitoringpt_BR
dc.subjectminimization of operational conditionspt_BR
dc.subjectstructural health monitoringpt_BR
dc.titleSeven years of continuous dynamic monitoring of baixo sabor dampt_BR
dc.typeconferenceObjectpt_BR
dc.identifier.localedicaoFeeecept_BR
dc.description.pages8p.pt_BR
dc.identifier.localAtenas, Gréciapt_BR
dc.description.sectorDBB/NMMRpt_BR
dc.identifier.conftitle9th International Conference on Computational Methods in Structural Dynamics and Earthquake Engineering, COMPDYN 2023pt_BR
dc.contributor.peer-reviewedSIMpt_BR
dc.contributor.academicresearchersSIMpt_BR
dc.contributor.arquivoSIMpt_BR
Appears in Collections:DBB/NMMR - Comunicações a congressos e artigos de revista

Files in This Item:
File Description SizeFormat 
Eurododin2023-1stpage.pdfPrimeira p?gina112.24 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.