Please use this identifier to cite or link to this item: http://repositorio.lnec.pt:8080/jspui/handle/123456789/1005315
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMata, J.pt_BR
dc.contributor.authorTavares de Castro, A.pt_BR
dc.contributor.authorSá da Costa, J. M.pt_BR
dc.contributor.editorElsevierpt_BR
dc.date.accessioned2013-10-29T16:31:26Zpt_BR
dc.date.accessioned2014-10-09T14:21:51Zpt_BR
dc.date.accessioned2017-04-13T12:11:22Z-
dc.date.available2013-10-29T16:31:26Zpt_BR
dc.date.available2014-10-09T14:21:51Zpt_BR
dc.date.available2017-04-13T12:11:22Z-
dc.date.issued2013-03-01pt_BR
dc.identifier.citationJ. Mata, A. Tavares de Castro, J. Sá da Costa. 2013. "Time–frequency analysis for concrete dam safety control: Correlation between the daily variation of structural response and air temperature". Engineering Structures, Elsevier.pt_BR
dc.identifier.otherhttp://dx.doi.org/10.1016/j.engstruct.2012.12.013pt_BR
dc.identifier.urihttps://repositorio.lnec.pt/jspui/handle/123456789/1005315-
dc.description.abstractThe purpose of this research work is to identify the effect of the daily variation of the air temperature on the structural response of a concrete dam. It is intended to obtain a better knowledge about structural behaviour of concrete dams. In current day to day activities, quantitative interpretation models are used for the assessment of structural dam behaviour of concrete dams. Most models ignore the temperature effect of a wave with a daily variation. However, in dams with automated data acquisition systems this daily effect can be used to anticipate the detection of abnormal behaviour. In this paper, the Short Time Fourier Transform analysis of the residuals is used, obtained by the quantitative interpretation models and measurement data, to identify the signature that the daily variation of the air temperature has on the structural behaviour of a concrete dam. A case study is presented based on the analysis of a horizontal displacement measured on a pendulum, in the Alto Lindoso concrete dam. As a result, the relation between magnitudes of daily variations of the horizontal displacement analysed and the air temperature was defined. The relation obtained can be used to assess if there is alterations or not in the dam response to short period loads corresponding to the daily variations analysed.pt_BR
dc.description.sponsorshipLNEC e FCT através da bolsa de doutoramento SFRH/BD/75876/2011.pt_BR
dc.language.isoengpt_BR
dc.publisherElsevierpt_BR
dc.rightsopenAccesspt_BR
dc.subjectStructural health monitoringpt_BR
dc.subjectConcrete dam behaviourpt_BR
dc.subjectSpectral analysispt_BR
dc.subjectShort time fourier transformpt_BR
dc.subjectQuantitative modelspt_BR
dc.subjectAutomated data acquisition systempt_BR
dc.titleTime–frequency analysis for concrete dam safety control: Correlation between the daily variation of structural response and air temperaturept_BR
dc.typearticlept_BR
dc.description.figures10pt_BR
dc.description.tables1pt_BR
dc.description.pages8ppt_BR
dc.description.volume48pt_BR
dc.description.sectorDBB/NOpt_BR
dc.description.magazineEngineering Structurespt_BR
Appears in Collections:DBB/NO - Comunicações a congressos e artigos de revista

Files in This Item:
File Description SizeFormat 
Elsevier2013.pdf971.49 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.