dc.description.abstractThis paper presents the application of a methodology which can be used to assess arch dam foundation stability, using the discrete element method (DEM) and the code 3DEC. A global three-dimensional model of a dam foundation was developed, in which some discontinuities were simulated and both the grout and drainage curtains were represented. The model, calibrated taking into account recorded data, was used to carry out non-linear mechanical analysis. The same model was employed to perform a hydraulic analysis, based on equivalent continuum concepts, which allowed the water pressure pattern within the foundation to be obtained. These water pressures were applied on discontinuities involved in the possible sliding mechanism along the dam/foundation interface, and the safety of the dam/foundation system was evaluated using a process of reduction of strength characteristics, with the aim of calculating the minimum safety factors that ensure stability. Results were compared with those obtained with the usual bi-linear uplift pressure distribution at the base of the dam, commonly used in concrete dam design. The relevance of carrying out hydraulic analysis in arch dam foundation failure studies is highlighted.pt_BR
dc.language.isoengpt_BR
dc.publisherSpringerpt_BR
dc.rightsopenAccesspt_BR
dc.subjectConcrete damspt_BR
dc.subjectRock foundationspt_BR
dc.subjectHydromechanical behaviorpt_BR
dc.subjectFailure analysispt_BR
dc.titleAnalysis of foundation sliding of an arch dam considering the hydromechanical behaviorpt_BR
dc.typearticlept_BR
dc.description.figures11pt_BR
dc.description.pages9ppt_BR
dc.description.volumevol 6; issue 1pt_BR
dc.description.sectorDBB/NOpt_BR
dc.description.magazineFrontiers of Structural and Civil Engineeringpt_BR
Appears in Collections:DBB/NO - Comunicações a congressos e artigos de revista

Files in This Item:
File Description SizeFormat 
Farinha_Lemos_Maranha_FSCE_2012_fulltext.pdf741.74 kBAdobe PDFView/Open