Please use this identifier to cite or link to this item: http://repositorio.lnec.pt:8080/jspui/handle/123456789/16822
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRibeiro, A.pt_BR
dc.contributor.authorLages Martins, L.pt_BR
dc.contributor.authorSousa, J. A.pt_BR
dc.contributor.authorBaptista, R.pt_BR
dc.contributor.editorCollège Français de Metrologiept_BR
dc.date.accessioned2009-10-01T13:54:04Zpt_BR
dc.date.accessioned2010-04-20T13:52:47Zpt_BR
dc.date.accessioned2014-10-09T11:22:28Zpt_BR
dc.date.accessioned2017-04-13T11:28:50Z-
dc.date.available2009-10-01T13:54:04Zpt_BR
dc.date.available2010-04-20T13:52:47Zpt_BR
dc.date.available2014-10-09T11:22:28Zpt_BR
dc.date.available2017-04-13T11:28:50Z-
dc.date.issued2009-10-01T13:54:04Zpt_BR
dc.identifier.otherVersão Electrónicapt_BR
dc.identifier.urihttps://repositorio.lnec.pt/jspui/handle/123456789/16822-
dc.description.abstractManagement systems developed according to ISO/IEC 17025 must fulfil several requirements, being particularly relevant the assurance of the measurement results quality. The enhancement of that quality depends upon several conditions, one of which is the instrumentation metrological performance and its service conditions along its lifetime. In this context, the evaluation of long time drifts in the instrumentation metrological performance is a major concern requiring the development of calibration planning under traceable conditions, to determine possible corrections and to establish the best measurement capabilities. The periodicity of the calibration operations is a technical decision with considerable implications in the system management performance (namely, operational costs and management of decision risk). Although this decision can be significantly cost effective, many industries and laboratories apply recommended calibration intervals regardless of any type of data analysis concerning aspects such as the severity of use and the different accuracy requirements associated with specific applications. Considering that there is a relation between the calibration intervals and the expectations of “failure” of a measurement instrument (“failure” meaning that the instrument will be out-of-tolerance considering its own usage requirements), to combine the stochastic nature of the problem with statistical methods to predict the optimized calibration interval is a challenge to many management systems. The effort towards this optimization requires prior knowledge of critical variables, the history of calibration data, methods and models suitable to perform the statistical analysis of the collected data. The optimized definition of the calibration intervals based in statistical analysis can provide robust solutions, allowing the improvement of the management system in both economical and quality performances. This paper presents concepts, discusses methods, models and their variables that can be used to define calibration intervals. Moreover, a reliability approach to a cost-effectiveness analysis is also presented. Some examples concerning the experience of the above mentioned metrological laboratories are used in order to enhance some of the remarks and conclusions.pt_BR
dc.format.extent295187 bytespt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoengpt_BR
dc.rightsopenAccesspt_BR
dc.subjectCalibration intervalpt_BR
dc.subjectManagement systempt_BR
dc.subjectCalibrationpt_BR
dc.titleMethods for the definition of calibration intervals and to perform cost-efectiveness analysis in management systemspt_BR
dc.typeconferenceObjectpt_BR
dc.identifier.localedicaoParis, Françapt_BR
dc.description.figures6pt_BR
dc.description.tables8pt_BR
dc.description.pages6pppt_BR
dc.identifier.seminario14.º Congrès International de Metrologiept_BR
dc.identifier.localParis, Françapt_BR
dc.description.sectorCIC/NQMpt_BR
dc.name.labelMETROLOGIApt_BR
dc.description.year2009pt_BR
dc.description.data22 a 25 de Junhopt_BR
Appears in Collections:CICTI/NQM - Comunicações a congressos e artigos de revista

Files in This Item:
File Description SizeFormat 
Metrologie_2009_ASRibeiro_et_al.pdf288.27 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.