Please use this identifier to cite or link to this item:
http://repositorio.lnec.pt:8080/jspui/handle/123456789/17940
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Viegas, J. | pt_BR |
dc.contributor.editor | Elsevier | pt_BR |
dc.date.accessioned | 2010-02-15T12:13:31Z | pt_BR |
dc.date.accessioned | 2010-04-21T15:14:13Z | pt_BR |
dc.date.accessioned | 2014-10-10T09:18:30Z | pt_BR |
dc.date.accessioned | 2016-06-21T10:01:00Z | - |
dc.date.available | 2010-02-15T12:13:31Z | pt_BR |
dc.date.available | 2010-04-21T15:14:13Z | pt_BR |
dc.date.available | 2014-10-10T09:18:30Z | pt_BR |
dc.date.available | 2016-06-21T10:01:00Z | - |
dc.date.issued | 2009-09-13 | pt_BR |
dc.identifier.citation | Tunnelling and Underground Space Technology 25 | pt_BR |
dc.identifier.uri | https://repositorio.lnec.pt/jspui/handle/123456789/17940 | - |
dc.description.abstract | Impulse ventilation systems (IVS) are used to provide ventilation for covered car parks and to control the smoke in the event of fire. In this paper the interaction between the fire ceiling jet and the flow driven by jet fans is studied using CFD simulations. A sensitivity analysis considering important parameters as position and intensity of fire source, transversal distance between jet fans, restriction of exhaust flow rate and dimension of car park exhaust opening is carried out and rules for the design of 50 N thrust jet fans are deduced. An analytical model for the flow field near the ceiling is developed and compared with CFD simulations. This model is intended to support a first approach of the design of IVS. 2009 Elsevier Ltd. All rights reserved. | pt_BR |
dc.format.extent | 1478690 bytes | pt_BR |
dc.format.mimetype | application/pdf | pt_BR |
dc.language.iso | eng | pt_BR |
dc.publisher | Elsevier | pt_BR |
dc.relation.ispartofseries | Vol. 25 | pt_BR |
dc.rights | restrictedAccess | pt_BR |
dc.subject | Impulse ventilation | pt_BR |
dc.subject | Covered car park | pt_BR |
dc.subject | Jet fan | pt_BR |
dc.subject | Smoke control | pt_BR |
dc.subject | Cfd | pt_BR |
dc.title | The use of impulse ventilation for smoke control in underground car parks | pt_BR |
dc.type | workingPaper | pt_BR |
dc.description.figures | 17 | pt_BR |
dc.description.pages | 42-53pp | pt_BR |
dc.description.sector | DED/NAICI | pt_BR |
Appears in Collections: | DED/NAICI - Comunicações a congressos e artigos de revista |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.