Please use this identifier to cite or link to this item:
http://repositorio.lnec.pt:8080/jspui/handle/123456789/17218
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Pereira, E. V. | pt_BR |
dc.contributor.author | Figueira, R. | pt_BR |
dc.contributor.author | Salta, M. M. | pt_BR |
dc.contributor.author | Fonseca, I. | pt_BR |
dc.date.accessioned | 2009-11-09T10:12:41Z | pt_BR |
dc.date.accessioned | 2010-04-27T07:25:22Z | pt_BR |
dc.date.accessioned | 2014-10-20T16:32:14Z | pt_BR |
dc.date.accessioned | 2017-04-13T11:11:35Z | - |
dc.date.available | 2009-11-09T10:12:41Z | pt_BR |
dc.date.available | 2010-04-27T07:25:22Z | pt_BR |
dc.date.available | 2014-10-20T16:32:14Z | pt_BR |
dc.date.available | 2017-04-13T11:11:35Z | - |
dc.date.issued | 2009-10-26 | pt_BR |
dc.identifier.issn | doi:10.3390/s91108391 | pt_BR |
dc.identifier.uri | https://repositorio.lnec.pt/jspui/handle/123456789/17218 | - |
dc.description.abstract | This work reports a study carried out on the design and performance of galvanic and polarization resistance sensors to be embedded in concrete systems for permanent monitoring of the corrosion condition of reinforcing steel, aiming to establish a correlation between the galvanic currents, Igal, and the corrosion currents, Icorr, estimated from the polarization resistance, Rp. Sensors have been tested in saturated Ca(OH)2 aqueous solutions, under a variety of conditions, simulating the most important parameters that can accelerate the corrosion of concrete reinforcing steel, such as carbonation, ingress of chloride ions, presence or absence of O2. For all the conditions, the influence of temperature (20 to 55 ºC) has also been considered. From this study, it could be concluded that the galvanic currents are sensitive to the various parameters following a trend similar to that of the Rp values. A relationship between the galvanic and the corrosion current densities was obtained and the limiting values of the Igal, indicative of the state condition of the reinforcing steel for the designed sensor, were established | pt_BR |
dc.description.sponsorship | The financial support of FCT and FEDER through the program POCI 2010 (Project POCI/ECM/55692/2004) is grateful acknowledged. Financial support from “Fundação para a Ciência e Tecnologia” to “Centro de Ciências Moleculares e Materiais” is also grateful acknowledged. | pt_BR |
dc.format.extent | 2946 bytes | pt_BR |
dc.format.mimetype | application/pdf | pt_BR |
dc.language.iso | eng | pt_BR |
dc.publisher | MDPI Publishing, Sensors (ISSN 1424-8220; CODEN: SENSC9) | pt_BR |
dc.rights | openAccess | pt_BR |
dc.subject | Galvanic sensor | pt_BR |
dc.subject | Polarization resistance sensor | pt_BR |
dc.subject | Corrosion rate | pt_BR |
dc.title | A galvanic sensor for monitoring the corrosion condition of the concrete reinforcing steel: Relation between the galvanic and the corrosion currents | pt_BR |
dc.type | article | pt_BR |
dc.description.figures | 6 | pt_BR |
dc.description.tables | 2 | pt_BR |
dc.description.pages | 8391-8398 | pt_BR |
dc.description.volume | 9 | pt_BR |
dc.description.sector | DM/NMM | pt_BR |
dc.name.label | Sensors 2009, 9, pp 8391-8398 | pt_BR |
dc.name.label | Latest Impact Factor: 1.870 (for 2008) | pt_BR |
dc.description.year | 2009 | pt_BR |
Appears in Collections: | DM/NMM - Comunicações a congressos e artigos de revista |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Dspace.pdf | 2.88 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.