Please use this identifier to cite or link to this item: http://repositorio.lnec.pt:8080/jspui/handle/123456789/1013729
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPinto, M.pt_BR
dc.contributor.authorLanzinha, J. C. G.pt_BR
dc.contributor.authorViegas, J.pt_BR
dc.contributor.authorInfante, A.pt_BR
dc.contributor.authorFreire, T.pt_BR
dc.contributor.editorInternational Journal of Sustainable Building Technology and Urban Developmentpt_BR
dc.date.accessioned2021-05-18T14:18:37Zpt_BR
dc.date.accessioned2021-06-30T11:07:20Z-
dc.date.available2021-05-18T14:18:37Zpt_BR
dc.date.available2021-06-30T11:07:20Z-
dc.date.issued2021-04pt_BR
dc.identifier.citationhttps://doi.org/10.22712/susb.20210004pt_BR
dc.identifier.issn2093-761Xpt_BR
dc.identifier.issn2093-7628pt_BR
dc.identifier.urihttps://repositorio.lnec.pt/jspui/handle/123456789/1013729-
dc.description.abstractThe Indoor Environment Quality study takes on a very significant challenge when analyzed, mainly, in buildings that encompass a more sensitive and susceptible type of population, as is the case of children. To comply with a set of requirements, namely the concentration of pollutants and the conditions of hygrothermal comfort, is a necessary condition to keep an interior environment suitable for the permanence of the occupants. A research project, that studied Indoor Environment Quality in four buildings which hold nurseries and kindergartens, was carried out in two cities in central Portugal, Viseu and Covilhã. The following main conclusions may be drawn: most compartments are not comfortable in terms of ambient temperature, but the relative humidity has reasonable values. Air change rates generally have low values and the measured pollutants have worrying values. Based on the observed problems and reached conclusions, some recommendations are proposed.pt_BR
dc.language.isoengpt_BR
dc.publisherInternational Journal of Sustainable Building Technology and Urban Developmentpt_BR
dc.rightsrestrictedAccesspt_BR
dc.subjectindoor environment quality (IEQ)pt_BR
dc.subjectindoor air quality (IAQ)pt_BR
dc.subjectnurseriespt_BR
dc.subjectkindergartens (KGT)pt_BR
dc.subjecthygrothermal comfortpt_BR
dc.subjectair change ratespt_BR
dc.titleKindergartens and nurseries in central Portugal. Assessments of indoor environment qualitypt_BR
dc.typeworkingPaperpt_BR
dc.description.pages27-43pt_BR
dc.description.volumeVol. 12, N.º 1pt_BR
dc.description.sectorCIC/CHEFIApt_BR
dc.description.magazineInternational Journal of Sustainable Building Technology and Urban Developmentpt_BR
dc.contributor.peer-reviewedSIMpt_BR
dc.contributor.academicresearchersSIMpt_BR
dc.contributor.arquivoNAOpt_BR
Appears in Collections:CICTI/Chefia - Comunicações a congressos e artigos de revista

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.