Please use this identifier to cite or link to this item:
http://repositorio.lnec.pt:8080/jspui/handle/123456789/1009764
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Gaspar, F. | pt_BR |
dc.contributor.author | Cruz, H. | pt_BR |
dc.contributor.author | Gomes, A. | pt_BR |
dc.contributor.editor | K. Richter; J.-W. Van de Kuilen | pt_BR |
dc.date.accessioned | 2017-07-27T09:56:15Z | pt_BR |
dc.date.accessioned | 2017-08-08T14:24:31Z | - |
dc.date.available | 2017-07-27T09:56:15Z | pt_BR |
dc.date.available | 2017-08-08T14:24:31Z | - |
dc.date.issued | 2017-09-15 | pt_BR |
dc.identifier.citation | DOI 10.1007/s00107-017-1217-4 | pt_BR |
dc.identifier.issn | 0018-3768 (Print) 1436-736X (Online) | pt_BR |
dc.identifier.other | DOI 10.1007/s00107-017-1217-4 | pt_BR |
dc.identifier.uri | https://repositorio.lnec.pt/jspui/handle/123456789/1009764 | - |
dc.description.abstract | Monitoring and evaluation of glued laminated timber structures in service is essential to warrant its integrity, where non-destructive techniques play an important role. This paper describes the results obtained on glued laminated timber beams of maritime pine, with and without preservative treatment, and of spruce, exposed to natural outdoor environment as well as to artificial weathering. The assessment of glue lines’ shear strength was investigated through the extraction and testing of cores parallel and perpendicular to the glued lines and block shear specimens with 50 mm × 50 mm and 20 mm × 20 mm shear area. The results highlight the different performances of the various types of specimens tested, showing that the measured shear strength depends on the specimen size and that the size effect depends on the material strength giving a decreasing modification factor with the increase of strength in opposition to the constant factor suggested by standard EN 14080. They also show that shear testing of cores drilled perpendicular to the glued joints may be a promising tool in the assessment of glulam structures on site. | pt_BR |
dc.language.iso | eng | pt_BR |
dc.publisher | Springer-Verlag GmbH Germany 2017 | pt_BR |
dc.rights | restrictedAccess | pt_BR |
dc.subject | Laminated timber structures | pt_BR |
dc.title | Evaluation of glue line shear strength of laminated timber structures using block and core type specimens | pt_BR |
dc.type | workingPaper | pt_BR |
dc.description.pages | 13p | pt_BR |
dc.description.comments | The authors wish to thank Fundação para a Ciência e a Tecnologia (Portuguese Foundation for Science and Technology), for the PhD Grant (Number SFRH/BD/30310/2006) given to Florindo Gaspar | pt_BR |
dc.description.sector | DE/NCE | pt_BR |
dc.description.magazine | European Journal of Wood and Wood Products | pt_BR |
dc.contributor.peer-reviewed | SIM | pt_BR |
dc.contributor.academicresearchers | SIM | pt_BR |
dc.contributor.arquivo | NAO | pt_BR |
Appears in Collections: | DE/NCE - Comunicações a congressos e artigos de revista |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.