dc.description.abstractABSTRACT: This communication presents a set of experimental results and numerical evaluations, characterizing the air permeability and ventilation system of a “Gaioleiro” building. Regarding the high rates of air infiltration obtained, namely by old wooden windows, it was studied retrofit measures for building airtightness and ventilation system. The results presented in this article show a great potential for building thermal performance improvement, regarding only the retrofit of building airtightness (window improvement or window replacement). In this article it’s also shown the threat of getting bad ventilation after sealing the building envelope. The air permeability evaluation was determined using the fan pressurization method (EN 13829:2000). The ventilation air flow rate was evaluated with tracer gas concentration decay method (EN ISO 12569:2000). Air flow rates calculation, for current construction and retrofit measures, was carried out using numerical model (EN 15242:2007), validated with the experimental results obtained.pt_BR
dc.language.isoporpt_BR
dc.publisherLNECpt_BR
dc.rightsopenAccesspt_BR
dc.subjectVentilaçãopt_BR
dc.subjectO a ipt_BR
dc.subjectPermeabilidadept_BR
dc.subjectEficiência energéticapt_BR
dc.subjectPressurizaçãopt_BR
dc.subjectReabilitaçãopt_BR
dc.subjectEdifício gaioleiropt_BR
dc.subjectTémicapt_BR
dc.subjectSimulaçãopt_BR
dc.subjectEnsaiopt_BR
dc.titleAvaliação experimental da permeabilidade ao ar da envolvente e do sistema de ventilação. Edifício "Gaioleiro" (1880)pt_BR
dc.typeconferenceObjectpt_BR
dc.identifier.localedicaoLNEC/DEDpt_BR
dc.description.figures2pt_BR
dc.description.tables7pt_BR
dc.description.pages8ppt_BR
dc.identifier.seminarioConferência Nacional 2011pt_BR
dc.identifier.localLisboapt_BR
dc.identifier.localizacaoNAICIpt_BR
dc.description.sectorDED/NAICIpt_BR
dc.description.year2011pt_BR
dc.description.data29 e 30 de Setembropt_BR
Appears in Collections:DED/NAICI - Comunicações a congressos e artigos de revista

Files in This Item:
File Description SizeFormat 
Filipe.docx640.95 kBMicrosoft Word XMLView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.