Please use this identifier to cite or link to this item: http://repositorio.lnec.pt:8080/jspui/handle/123456789/17446
Full metadata record
DC FieldValueLanguage
dc.contributor.authorViegas, J.pt_BR
dc.contributor.authorCruz, H.pt_BR
dc.contributor.authorVilar, F.pt_BR
dc.contributor.authorNeves, C.pt_BR
dc.contributor.authorGalhardas, H.pt_BR
dc.contributor.authorCoelho, P.pt_BR
dc.date.accessioned2009-12-10T10:46:25Zpt_BR
dc.date.accessioned2010-04-21T15:11:30Zpt_BR
dc.date.accessioned2014-10-10T09:18:28Zpt_BR
dc.date.accessioned2016-06-21T10:27:42Z-
dc.date.available2009-12-10T10:46:25Zpt_BR
dc.date.available2010-04-21T15:11:30Zpt_BR
dc.date.available2014-10-10T09:18:28Zpt_BR
dc.date.available2016-06-21T10:27:42Z-
dc.date.issued2009-10-21pt_BR
dc.identifier.urihttps://repositorio.lnec.pt/jspui/handle/123456789/17446-
dc.description.abstractImpulse ventilation systems (IVS) have been used for years to provide longitudinal ventilation in tunnels. In last 15 years these systems have been applied also to underground car parks. However, the design of such systems is not yet well defined and their performance was never compared to ducted ventilation systems. A research project on this subject is presented and the preliminary results of the survey of ventilation relevant quantities in enclosed car parks in use (project task 1) are also presented. Results show that the first predictions of carbon monoxide average concentration are compatible with measurements and that some peaks of CO concentration occur. The activation of jet fans and increment of ventilation rate dilute very fast the pollution peaks. Pollution peaks seem to be associated to local concentration of vehicle engines working or working close to CO detectors.pt_BR
dc.format.extent1922632 bytespt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoengpt_BR
dc.rightsrestrictedAccesspt_BR
dc.subjectImpulse ventilationpt_BR
dc.subjectJet fanspt_BR
dc.subjectCar parkspt_BR
dc.subjectExperimentspt_BR
dc.titleImpulse ventilation for pollution control in underground car parkspt_BR
dc.typeworkingPaperpt_BR
dc.description.figures4pt_BR
dc.description.tables2pt_BR
dc.description.pages6ppt_BR
dc.identifier.seminarioConferência internacional de ventilação industrialpt_BR
dc.identifier.localZuriquept_BR
dc.description.sectorDED/NAICIpt_BR
dc.description.year2009pt_BR
dc.description.data18 a 21 de Outubropt_BR
Appears in Collections:DED/NAICI - Comunicações a congressos e artigos de revista

Files in This Item:
There are no files associated with this item.