DC Field | Value | Language |
---|---|---|
dc.contributor.author | Veiga, M. R. | pt_BR |
dc.contributor.author | Lopes dos Santos, A. R. | pt_BR |
dc.contributor.author | Santos, D. | pt_BR |
dc.date.accessioned | 2022-03-24T10:43:55Z | pt_BR |
dc.date.accessioned | 2022-04-08T08:44:32Z | - |
dc.date.available | 2022-03-24T10:43:55Z | pt_BR |
dc.date.available | 2022-04-08T08:44:32Z | - |
dc.date.issued | 2015-09 | pt_BR |
dc.identifier.uri | https://repositorio.lnec.pt/jspui/handle/123456789/1014743 | - |
dc.description.abstract | Mortars for renders and plasters should verify a number of requirements to be functional and durable, which are related to: compatibility with other materials in the building, especially the substrate; environment and climatic conditions which they are exposed to; required functions in the building. For old buildings the balance between functional performance and compatibility requirements is sometimes a demanding issue. The binder defines to a certain point the mortar’s characteristics. Natural hydraulic limes NHL are under the scope of the European Standard EN 459-1:2010 that establishes now rather restrict and clear rules for their composition and characteristics. In this work, results of the characterization of a natural hydraulic lime NHL 3.5 produced in Portugal and of mortars with NHL 3.5 as a binder are presented. Two different sand natures and several proportions lime : sand are used. Results of tests in laboratory and in situ are presented and discussed considering the use of the mortars for rehabilitation of old buildings. | pt_BR |
dc.language.iso | eng | pt_BR |
dc.publisher | Building Limes Forum | pt_BR |
dc.rights | restrictedAccess | pt_BR |
dc.subject | mortar | pt_BR |
dc.subject | natural hydraulic lime | pt_BR |
dc.subject | performance | pt_BR |
dc.subject | compatibility | pt_BR |
dc.title | Natural hydraulic lime mortars for rehabilitation of old buildings: Compatibility and performance | pt_BR |
dc.type | workingPaper | pt_BR |
dc.identifier.localedicao | Cambridge, Inglaterra | pt_BR |
dc.description.pages | 11p | pt_BR |
dc.identifier.local | Cambridge, Inglaterra | pt_BR |
dc.description.sector | DED/NRI | pt_BR |
dc.identifier.conftitle | Conference and Gathering of the Building Limes Forum 2015, Building Limes Forum | pt_BR |
dc.contributor.peer-reviewed | NAO | pt_BR |
dc.contributor.academicresearchers | NAO | pt_BR |
dc.contributor.arquivo | NAO | pt_BR |
Appears in Collections: | DED/NRI - Comunicações a congressos e artigos de revista |