Please use this identifier to cite or link to this item:
http://repositorio.lnec.pt:8080/jspui/handle/123456789/1012901
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Correia, A.A. | pt_BR |
dc.contributor.author | Mera Marques, A. | pt_BR |
dc.contributor.author | Campos Costa, A. | pt_BR |
dc.contributor.author | Candeias, P. | pt_BR |
dc.contributor.author | Bernardo, V. | pt_BR |
dc.contributor.author | Tomassetti, U. | pt_BR |
dc.contributor.author | Graziotti, F. | pt_BR |
dc.contributor.author | Kallioras, S. | pt_BR |
dc.date.accessioned | 2020-08-17T15:27:14Z | pt_BR |
dc.date.accessioned | 2020-09-03T11:00:47Z | - |
dc.date.available | 2020-08-17T15:27:14Z | pt_BR |
dc.date.available | 2020-09-03T11:00:47Z | - |
dc.date.issued | 2019-04 | pt_BR |
dc.identifier.uri | https://repositorio.lnec.pt/jspui/handle/123456789/1012901 | - |
dc.description.abstract | The response of three full-scale unreinforced masonry buildings, without specific seismic detailing, as observed in shake table testing at LNEC for a seismic action representative of induced seismicity, is presented. The first building specimen simulated the upper floor and roof of the end-unit of a two-storey terraced house, built with unreinforced cavity walls, a reinforced concrete slab and a pitched timber roof. The second specimen was a replica of the roof of the first building. The third specimen represented instead a one-story detached pre-1940’s house, built with double-wythe unreinforced clay masonry walls, a timber floor and a steep-pitch roof supported on timber trusses. The specimens were tested up to partial collapse or near-collapse conditions. This paper summarises the main characteristics of the specimens and their experimental results, illustrating their dynamic response and the evolution of damage. | pt_BR |
dc.language.iso | eng | pt_BR |
dc.publisher | Comissão Organizadora | pt_BR |
dc.rights | restrictedAccess | pt_BR |
dc.subject | Unreinforced masonry building | pt_BR |
dc.subject | Full-scale shake table test | pt_BR |
dc.subject | Induced seismicity | pt_BR |
dc.subject | Limit states | pt_BR |
dc.subject | Collapse | pt_BR |
dc.title | Experimental response of non-seismically designed URM buildings subjected to induced seismicity | pt_BR |
dc.type | workingPaper | pt_BR |
dc.description.pages | 12p | pt_BR |
dc.identifier.local | IST, Lisboa | pt_BR |
dc.description.sector | DE/NESDE | pt_BR |
dc.identifier.conftitle | 11º Congresso nacional de sismologia e engenharia sísmica (SISMICA 2019) | pt_BR |
dc.contributor.peer-reviewed | SIM | pt_BR |
dc.contributor.academicresearchers | SIM | pt_BR |
dc.contributor.arquivo | NAO | pt_BR |
Appears in Collections: | DE/NESDE - Comunicações a congressos e artigos de revista |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.