Please use this identifier to cite or link to this item:
http://repositorio.lnec.pt:8080/jspui/handle/123456789/1011195
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lança, M. | pt_BR |
dc.contributor.author | Coelho, P. J. | pt_BR |
dc.contributor.author | Viegas, J. | pt_BR |
dc.date.accessioned | 2018-12-28T14:53:11Z | pt_BR |
dc.date.accessioned | 2019-02-07T15:13:57Z | - |
dc.date.available | 2018-12-28T14:53:11Z | pt_BR |
dc.date.available | 2019-02-07T15:13:57Z | - |
dc.date.issued | 2018-11-28 | pt_BR |
dc.identifier.citation | https://doi.org/10.1016/j.buildenv.2018.11.033 | pt_BR |
dc.identifier.uri | https://repositorio.lnec.pt/jspui/handle/123456789/1011195 | - |
dc.description.abstract | Most office buildings are designed to be ventilated and cooled using mechanical systems. However, in a temperate climate, passive ventilation and cooling techniques can reduce energy consumption when the outdoor temperatures are favourable, e.g., at night. Nevertheless, decorative components like the suspended ceiling (SC) contribute to insulation, preventing the desired thermal exchange with the slab. This work investigates an innovative solution to the optimization of the night cooling phenomenon by using a SC with a peripheral gap and taking advantage of the plenum formed by the space between the slab and the SC for cooling purposes. The experiments were carried out on a reduced scale model. It was found that a SC with a gap allows part of the heat dissipated in the room during the occupation period to be used to heat the slab, thus reducing the air temperature during the day, in comparison with a conventional SC with no gap. Moreover, a SC with a gap, and with supply and extraction slots placed above it, improves the air cooling during the night, and reduces the temperatures in the occupation zone during the following day, in comparison with a conventional SC with no gap, and with the ventilation slots located below it. | pt_BR |
dc.language.iso | eng | pt_BR |
dc.publisher | Elsevier Ltd. | pt_BR |
dc.rights | restrictedAccess | pt_BR |
dc.subject | Night cooling | pt_BR |
dc.subject | Suspended ceiling | pt_BR |
dc.subject | Natural ventilation | pt_BR |
dc.subject | Sustainable buildings | pt_BR |
dc.title | Enhancement of heat transfer in office buildings during night cooling − reduced scale experimentation | pt_BR |
dc.type | workingPaper | pt_BR |
dc.description.pages | 653–667pp. | pt_BR |
dc.description.comments | Projeto financiado : UID/EMS/50022/2013 | pt_BR |
dc.description.volume | 148 (2019) | pt_BR |
dc.description.sector | CIC/CHEFIA | pt_BR |
dc.description.magazine | Building and Environment | pt_BR |
dc.contributor.peer-reviewed | SIM | pt_BR |
dc.contributor.academicresearchers | SIM | pt_BR |
dc.contributor.arquivo | NAO | pt_BR |
Appears in Collections: | CICTI/Chefia - Comunicações a congressos e artigos de revista |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.