Please use this identifier to cite or link to this item: http://repositorio.lnec.pt:8080/jspui/handle/123456789/1009419
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMarques da Silva, F.pt_BR
dc.contributor.authorGomes, M.pt_BR
dc.contributor.authorPereira, I.pt_BR
dc.contributor.authorPinto, A.pt_BR
dc.contributor.authorRodrigues. A.pt_BR
dc.date.accessioned2017-04-19T11:04:02Zpt_BR
dc.date.accessioned2017-08-08T14:24:08Z-
dc.date.available2017-04-19T11:04:02Zpt_BR
dc.date.available2017-08-08T14:24:08Z-
dc.date.issued2007-06pt_BR
dc.identifier.isbn978-952-99898-1-2pt_BR
dc.identifier.urihttps://repositorio.lnec.pt/jspui/handle/123456789/1009419-
dc.description.abstractDouble Skin Façades are characterized by having at least two membranes between the interior occupied space and the exterior environment, separated by an air gap. They are becoming a possible solution to design new and retrofitted aesthetic buildings, with a great visual connection to the outside. They also allow for the possibility of using natural ventilation techniques on buildings, even when subjected to great external noise and wind loads. This paper presents the results of two post-occupancy monitoring campaigns, during the summer and winter seasons respectively, on a DSF building situated in Lisbon. The experimental data showed a close dependency of the air gap temperatures on incoming radiation and outdoor temperature and also on the type of shading device. These results can provide useful information for the design of DSF configuration and ventilation strategies to achieve an overall performance improvement under typical Portuguese weather conditions.pt_BR
dc.language.isoengpt_BR
dc.publisherFINVACpt_BR
dc.rightsrestrictedAccesspt_BR
dc.subjectDouble skin façades (DSF)pt_BR
dc.subjectMonitored buildingpt_BR
dc.titleEvaluation of a double skin façade performance: results from summer and winter monitoringpt_BR
dc.typeworkingPaperpt_BR
dc.description.pages7ppt_BR
dc.identifier.localHelsinkipt_BR
dc.description.sectorDE/NESDEpt_BR
dc.identifier.conftitle10th International Conference on Air Distribution in Rooms - Roomvent 2007pt_BR
dc.contributor.peer-reviewedSIMpt_BR
dc.contributor.academicresearchersSIMpt_BR
dc.contributor.arquivoNAOpt_BR
Appears in Collections:DE/NESDE - Comunicações a congressos e artigos de revista

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.