Please use this identifier to cite or link to this item: http://repositorio.lnec.pt:8080/jspui/handle/123456789/1003716
Full metadata record
DC FieldValueLanguage
dc.contributor.authorReal, L. P.pt_BR
dc.contributor.editorRoger Brownpt_BR
dc.date.accessioned2012-08-23T12:20:14Zpt_BR
dc.date.accessioned2014-10-20T16:45:00Zpt_BR
dc.date.accessioned2017-04-13T08:53:37Z-
dc.date.available2012-08-23T12:20:14Zpt_BR
dc.date.available2014-10-20T16:45:00Zpt_BR
dc.date.available2017-04-13T08:53:37Z-
dc.date.issued2012-08pt_BR
dc.identifier.citationPolymer Testing 31 (2012) 963–969pt_BR
dc.identifier.urihttps://repositorio.lnec.pt/jspui/handle/123456789/1003716-
dc.description.abstractThe main goal of this work is to establish a correlation between the oxidation induction time (OIT) and the oxidation induction temperature (OIT*), which are frequently used to assess the thermo-oxidative stability of polyolefins, either as raw-materials or as finished products. Several tests have been performed at different temperatures (200, 210 and 220 C) using a set of polyethylene (PE) samples from different sources. The correlations found - based on a quadratic regression – make it possible to estimate the OIT value based on experimental data of OIT* and vice-versa. This method can be quite useful in cases when the PE is highly stabilized so that the OIT test at 200 C is expected to last for hours. Additionally, an Arrhenius plot has been developed to obtain the activation energy (Ea) associated with the beginning of the thermo-oxidation for each PE, which also allows us to determine OIT from calculated Ea. All estimated values, obtained by the developed regression models, using unknown specimens, have been confirmed by experimental testing. The regression models have also been checked by a residual analysis as a way to evaluate their reliability. The contribution of the uncertainties of measurement and calculation has also been evaluated, leading to increased reliability of the findings.pt_BR
dc.language.isoengpt_BR
dc.publisherElsevierpt_BR
dc.rightsopenAccesspt_BR
dc.subjectPolyethylenept_BR
dc.subjectDifferential scanning calorimetrypt_BR
dc.subjectThermoxidationpt_BR
dc.subjectOxidation induction time/temperaturept_BR
dc.titleA comparative study on the thermo-oxidative stability of polyethylenept_BR
dc.typearticlept_BR
dc.identifier.localedicaoLisboapt_BR
dc.description.figures4pt_BR
dc.description.tables6pt_BR
dc.description.pages963-969pt_BR
dc.description.volume31pt_BR
dc.description.sectorDM/NMOpt_BR
dc.identifier.proc0203/11/17694pt_BR
dc.description.magazinePolymer Testingpt_BR
Appears in Collections:DM/NMO - Comunicações a congressos e artigos de revista

Files in This Item:
File Description SizeFormat 
Polymer Testing 2012- OIT - article page 1.pdf57.37 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.