Please use this identifier to cite or link to this item: http://repositorio.lnec.pt:8080/jspui/handle/123456789/1002059
Title: Ultrasound velocity profile (UVP) measurements in shallow open-channel flows
Authors: Fernandes, J. N.
Leal, J. B.
Cardoso, A. H.
Issue Date: May-2010
Abstract: This paper is concerned with velocity measurements in shallow water flows by using Ultrasonic Velocity Profile (UVP) probes. The measurements were made in a 10 m long, 0.4 m wide flume whose slope is 0.00117. Diagonal and horizontal positioning of a single probe and the combination of two probes were tested as configurations of the UVP probes. Streamwise and transverse velocities were obtained. A sensitivity analysis was performed to UVP parameters, namely to the distance of the window for each measurement and to the distance between each measuring point. The influence of four different seeding materials was also assessed. Filters for eliminating noise and spikes were applied. For 1D measurements, UVP streamwise velocities were compared with Pitot tube measurements. For 2D measurements, streamwise velocities and turbulent intensities were compared with known laws. The results show the importance of i) setting optimal UVP parameters values, ii) of positioning adequately the UVP probes and iii) using appropriate seeding.
URI: https://repositorio.lnec.pt/jspui/handle/123456789/1002059
Appears in Collections:DHA/NRE - Comunicações a congressos e artigos de revista

Files in This Item:
File Description SizeFormat 
Fernandes et al _2010__final version.pdf1.62 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.