dc.description.abstractThe safety control of large dams requires the measurement of some important quantities that characterize their behavior (like absolute and relative displacements, strains and stresses in the concrete, discharges through the foundation, etc.) and on visual inspections of the structures. In the more important dams, the analysis of the measured data and their comparison with results of mathematical or physical models is determinant in the safety control decision process. The quality of the measurements assumes an important role in a dam’s safety assessment, namely in the detection of anomalous behavior related either to accident scenarios or to more delayed deterioration processes. In monitoring system devices operated manually, this quality depends on the order of magnitude of the measured quantity, on the technical characteristics of the measurement device and on the skills of the operator. This paper deals with the study of the direct influence of these factors on the quality of the monitoring system exploitation and indirectly on the global dam safety control process. The results of an analysis of the repeatability and reproducibility of measurements in a concrete dam are presented, allowing us to estimate the overall measurement error.pt_BR
dc.language.isoengpt_BR
dc.publisherATCOLD - Austrian National Committee on Large Damspt_BR
dc.rightsopenAccesspt_BR
dc.subjectConcretre dampt_BR
dc.subjectGrr studypt_BR
dc.subjectRepeatabilitypt_BR
dc.subjectReproducibilitypt_BR
dc.subjectAssessment of the measurement systempt_BR
dc.titleQuality Control of Dam Monitoring Measurementspt_BR
dc.typeconferenceObjectpt_BR
dc.identifier.localedicaoAustriapt_BR
dc.description.figures8pt_BR
dc.description.tables6pt_BR
dc.description.pages6pt_BR
dc.identifier.seminario8th ICOLD European Club Symposiumpt_BR
dc.identifier.localInnsbruck, Austriapt_BR
dc.identifier.localizacaoNOpt_BR
dc.description.sectorDBB/NOpt_BR
dc.description.year2010pt_BR
dc.description.data22 e 23 de Setembropt_BR