<?xml version="1.0" encoding="UTF-8"?>
<feed xmlns="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/">
  <title>Repositorio DSpace at LNEC</title>
  <link rel="alternate" href="http://repositorio.lnec.pt:8080" />
  <subtitle>The DSpace digital repository system captures, stores, indexes, preserves, and distributes digital research material.</subtitle>
  <id>http://repositorio.lnec.pt:8080</id>
  <updated>2026-11-06T18:49:35Z</updated>
  <dc:date>2026-11-06T18:49:35Z</dc:date>
  <entry>
    <title>Full-scale multipurpose ozonation in urban wastewater with strong textile input: removal of colour, micropollutants, pathogens and antimicrobial resistance indicators</title>
    <link rel="alternate" href="http://repositorio.lnec.pt:8080/jspui/handle/123456789/1020099" />
    <author>
      <name>Campinas, M.</name>
    </author>
    <author>
      <name>Vaz-Moreira, I.</name>
    </author>
    <author>
      <name>Viegas, R.M. C.</name>
    </author>
    <author>
      <name>Mesquita, E.</name>
    </author>
    <author>
      <name>Ribeiro, D.</name>
    </author>
    <author>
      <name>Ruivo, A.</name>
    </author>
    <author>
      <name>Soares, J.</name>
    </author>
    <author>
      <name>Paíga, P.</name>
    </author>
    <author>
      <name>Delerue-Matos, C.</name>
    </author>
    <author>
      <name>Faria, G.</name>
    </author>
    <author>
      <name>Silva, C.</name>
    </author>
    <author>
      <name>Costa, C.</name>
    </author>
    <author>
      <name>Manaia, C</name>
    </author>
    <author>
      <name>Rosa, M. J.</name>
    </author>
    <id>http://repositorio.lnec.pt:8080/jspui/handle/123456789/1020099</id>
    <updated>2026-09-04T11:04:54Z</updated>
    <published>2026-07-01T00:00:00Z</published>
    <summary type="text">Title: Full-scale multipurpose ozonation in urban wastewater with strong textile input: removal of colour, micropollutants, pathogens and antimicrobial resistance indicators
Authors: Campinas, M.; Vaz-Moreira, I.; Viegas, R.M. C.; Mesquita, E.; Ribeiro, D.; Ruivo, A.; Soares, J.; Paíga, P.; Delerue-Matos, C.; Faria, G.; Silva, C.; Costa, C.; Manaia, C; Rosa, M. J.
Abstract: Understanding multipurpose ozonation performance under realistic and variable wastewater conditions is critical for investment decisions under the revised EU Urban Wastewater Treatment Directive (EU-UWWTD). As most studies focuses on single treatment objectives or homogeneous municipal effluents, integrated evaluations are particularly needed for industry-influenced wastewaters, where ozone reactivity and process efficiency can differ markedly. This study aims to provide a holistic assessment of full-scale ozonation by simultaneously investigating the responses of chemical and biological contaminants, as well as microbial community dynamics, variable ozone doses applied primarily for textile colour control. To our knowledge, this is one of the first integrated full-scale studies of ozonation in a strongly textile-influenced urban WWTP (51% of total inflow). Ozonation performance was assessed through three full-scale experimental campaigns, each evaluating three ozone doses in the range of 0.4–1.0 mg O₃/mg TOC. The study evaluated colour removal, micropollutant abatement, pathogen and antimicrobial resistance (AMR) indicators reduction, by-product formation, acute toxicity and surrogate parameters for process monitoring. Ozonation had little effect on bulk organic parameters but achieved 50–84% colour removal and near-complete elimination of terrestrial humic-like fluorescence. High organic matter content and colour constrained ozone exposure, shifting micropollutant abatement towards predominantly •OH-driven oxidation. Nevertheless, ozonation alone achieved ≥80% removal of the monitored micropollutants at ozone doses ≥0.65 mg O₃/mg C, indicating its major contribution towards EU-UWWTD compliance targets. Somatic coliphages and bacteria log-reductions ranged from 0.9 to &gt;2.3 and from 0.2 to 1.2, respectively. Acute toxicity was reduced, whereas AMR gene abundance showed limited sensitivity to ozone dose. Post-treatment microbial regrowth was observed, particularly at higher ozone doses, including bacterial groups carrying resistance genes, suggesting a selection-like process. Operational surrogate indicators (A254, A436, colour-scan and PARAFAC components) were identified/validated to support process monitoring and EU-UWWTD implementation in complex wastewater matrices.</summary>
    <dc:date>2026-07-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Implementação de um instrumento de monitorização energética do parque edificado em Portugal</title>
    <link rel="alternate" href="http://repositorio.lnec.pt:8080/jspui/handle/123456789/1020098" />
    <author>
      <name>Fragoso, R.</name>
    </author>
    <author>
      <name>Monteiro, C. S.</name>
    </author>
    <author>
      <name>Brandão de Vasconcelos, A</name>
    </author>
    <author>
      <name>Santos, A. J.</name>
    </author>
    <author>
      <name>Pereira, S. S.</name>
    </author>
    <id>http://repositorio.lnec.pt:8080/jspui/handle/123456789/1020098</id>
    <updated>2026-09-04T11:04:47Z</updated>
    <published>2025-01-01T00:00:00Z</published>
    <summary type="text">Title: Implementação de um instrumento de monitorização energética do parque edificado em Portugal
Authors: Fragoso, R.; Monteiro, C. S.; Brandão de Vasconcelos, A; Santos, A. J.; Pereira, S. S.
Abstract: O Grupo de Coordenação da Estratégia de Longo Prazo para a Renovação de Edifícios (GCELPRE) visa dar cumprimento ao referido na Diretiva 2010/31/EU, do Parlamento Europeu e do Conselho, de 20 de maio de 2010, sobre o desempenho energético dos edifícios (alterada pela Diretiva (EU) 2018/844, do Parlamento Europeu e do Conselho, de 30 de maio de 2018), para apoiar a renovação, ate 2050, do parque nacional de edifícios residenciais e não residenciais, públicos e privados, com vista a obtenção de um parque imobiliário descarbonizado e de elevada eficiência energética, facilitando a sua transformação em edifícios com necessidades quase nulas de energia (NZEB).&#xD;
A avaliação de progresso da execução da ELPRE, a efetuar pelo Grupo de Coordenação, e feita com periodicidade bianual, existindo um relatório de progresso externo e acessível online e um relatório interno. Neste documento e apresentada uma síntese das atividades desenvolvidas, tendo por base o 7.o relatório deste GCELPRE, que resulta do trabalho desenvolvido pelo grupo no período entre dezembro de 2023 e novembro de 2024.</summary>
    <dc:date>2025-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Diagnosis of residual flow drivers in estuaries with the densimetric tidal Froude number</title>
    <link rel="alternate" href="http://repositorio.lnec.pt:8080/jspui/handle/123456789/1020097" />
    <author>
      <name>Khosravi, M.</name>
    </author>
    <author>
      <name>Fortunato, A. B.</name>
    </author>
    <author>
      <name>Lopez-Ruiz, A.</name>
    </author>
    <author>
      <name>Valle-Levinson, A.</name>
    </author>
    <author>
      <name>Garel, E.</name>
    </author>
    <id>http://repositorio.lnec.pt:8080/jspui/handle/123456789/1020097</id>
    <updated>2026-09-04T10:16:08Z</updated>
    <published>2026-07-01T00:00:00Z</published>
    <summary type="text">Title: Diagnosis of residual flow drivers in estuaries with the densimetric tidal Froude number
Authors: Khosravi, M.; Fortunato, A. B.; Lopez-Ruiz, A.; Valle-Levinson, A.; Garel, E.
Abstract: Diagnosis of Residual Flow Drivers in Estuaries with the Densimetric Tidal Froude
Number

Residual circulation in estuaries drives salt intrusion, material transport, and ecosystem
functioning. Yet the ability to diagnose its dominant forcing mechanism remains a
challenge. While previous studies suggest that the densimetric tidal Froude number
(Frt) may distinguish tidal from baroclinic forcing, its reliability across varying estuarine
conditions and spatial scales requires systematic evaluation. This study investigates
whether Frt can reliably diagnose the dominant drivers of residual circulation in
estuaries by using a suite of process-oriented numerical simulations in an idealized
estuary–shelf system with Gaussian cross-channel bathymetry. The model
configuration spans a wide parameter space, including variations in tidal amplitude,
channel depth, lateral slope, and river discharge. Residual circulation regimes are
diagnosed using the ratio between the barotropic and baroclinic terms of the tidally
averaged, axial momentum equation obtained from the model outputs, together with
the transverse structure of residual flows, allowing direct comparison with Frt
predictions. This study demonstrates, for the first time, that Frt can reliably diagnose
the dominant driver of residual circulation when the density length scale is defined over
the shortest feasible axial distances. Crucially, the results show that the skill of Frt is
highly sensitive to this spatial scale: its performance deteriorates when the density
gradient is computed over lengths that extend into regions with heterogeneous forcing.
Across all simulations, Frt functions as a robust bulk indicator of tide-dominated,
density-dominated, and near-balanced regimes only when the density scale is
restricted to zones where the axial salinity gradient is approximately constant. Such
zones consistently occupy the seaward side of the peak salinity gradient. Within this
region, Frt emerges as a reliable diagnostic tool and offers practical value for field
applications that require identifying the prevailing residual-flow driver. Tidally driven
circulation is characterized by relatively high Frt values (0.53 ± 0.31), density-driven
circulation by low values (−0.23 ± 0.16), and near-balanced regimes occupy a narrow
transitional interval (0.12 ± 0.14) in which neither process exerts clear dominance.
Future research may evaluate how these thresholds vary with the estuarine
configuration.</summary>
    <dc:date>2026-07-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Swelling effects in a reinforced concrete pier of Foz Dão bridge (Portugal). First approach for modeling and behavior interpretation</title>
    <link rel="alternate" href="http://repositorio.lnec.pt:8080/jspui/handle/123456789/1020070" />
    <author>
      <name>Folgado Santos, C.</name>
    </author>
    <author>
      <name>Nuzzo, M.</name>
    </author>
    <author>
      <name>Dias, I. M.</name>
    </author>
    <author>
      <name>Xu, Min</name>
    </author>
    <author>
      <name>Oliveira Santos, L.</name>
    </author>
    <author>
      <name>Batista, A. L.</name>
    </author>
    <id>http://repositorio.lnec.pt:8080/jspui/handle/123456789/1020070</id>
    <updated>2026-09-04T10:16:03Z</updated>
    <published>2024-05-18T00:00:00Z</published>
    <summary type="text">Title: Swelling effects in a reinforced concrete pier of Foz Dão bridge (Portugal). First approach for modeling and behavior interpretation
Authors: Folgado Santos, C.; Nuzzo, M.; Dias, I. M.; Xu, Min; Oliveira Santos, L.; Batista, A. L.
Abstract: The degradation of the Foz do Dão bridge, that served the IP3 road and is located over the Aguieira dam reservoir, in Portugal, mainly due to the internal swelling reactions in concrete, resulting in visible cracking in its piers, led to the bridge re-placement in August 2015. Since 2009, this bridge has been subject to several in-spections, including underwater inspections, laboratory tests of cores, as well as periodic geometric levelling of the deck and ambient vibration tests. These actions were aimed to characterize its structural behaviour and to detect damage growth that might jeopardize safety.&#xD;
The aim of this work is to characterize and interpret the structural behaviour of the highest pier. For this purpose, a three-dimensional numerical model, which consid-ers the environmental conditions and the time-dependent behaviour of the concrete, was developed. The loads applied to the pier are the dead-weight of pier and the weight of the bridge deck, the pressure of the reservoir water, the effects of the thermal variations and of the swelling. The computing of the expansions considers the influence of the temperature and of the confining effect of the rebars and of the stress fields. The temperatures variations at the pier were computed using a thermal model. The model was calibrated considering data obtained by laboratory tests, on samples extracted from the bridge and by the deck levelling.</summary>
    <dc:date>2024-05-18T00:00:00Z</dc:date>
  </entry>
</feed>

